Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Boiler Direct And Indirect Steam Methods

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Boiler Direct And Indirect Steam Methods
  • Supply Capacity : 10 units/month :Boiler Direct And Indirect Steam Methods
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Direct & Indirect Heating Solutions - Industrial Boiler

    Direct & Indirect Heating Solutions. We are reckoned manufacturer and supplier of the finest grade Direct & Indirect Heating Solutions. Our product range includes Thermal Steam Boiler, Biomass Boiler, Horizontal Thermic Fluid Heater, Vertical …Get Price

  • Water Level Controls and Devices - National Board of

    A level indicator, whether it be a gage glass, indirect sensing method, or independent remote, is used on a steam boiler to provide a water level reading. A gage glass is the most common form of level indicator found on steam boilers.Get Price

  • 1. ENERGY PERFORMANCE ASSESSMENT OF BOILERS

    Basically Boiler efficiency can be tested by the following methods: 1) The Direct Method: Where the energy gain of the working fluid (water and steam) is compared with the energy content of the boiler fuel. 2) The Indirect Method: Where the efficiency is the difference between the losses and the energy input. 1.6 The Direct Method TestingGet Price

  • Indirect fired heater/ firetube design - Boiler and

    Dec 30, 2002 · In the reference section for the appendix it calls up literature that conations 1st principal calculation methods for fire tube type heaters. I have used these methods to write software in mathcad for the design of these types of heaters for both direct fired steam types and indirect API12K types.Get Price

  • Comparing Indirect vs Direct hot water - Hamworthy Heating

    Example – comparing efficiencies of direct and indirect fired hot water systems using the Part L method. Direct fired condensing water heater: 96% gross thermal efficiency. An indirect fired calorifier: 96% (taking the condensing boiler's gross seasonal efficiency). When producing hot water with return boiler temperatures likely to be 60°C or higher, the boiler is more likely to be Get Price

  • ASME PTC 4- iNdirect Method: Stack Loss Method

    ASME PTC-4 – Indirect Method: Stack Loss Method This method approximates the stack losses of a boiler to estimate boiler efficiency. Parameters The parameters needed to calculate this method are given below. These data are calculated during source testing. 1. Stack temperature (T Stack) 2. Dry oxygen in flue gas (O 2,Dry,%) in percentGet Price

  • Boiler efficiency analysis using direct method | Request PDF

    The efficiency in steam boilers is calculated by two methods, Direct Method (Input-Output method) and Indirect Method (Heat Loss Method) [20]. The Direct Method is assumed by measuring through Get Price

  • boiler efficiency calculation indirect method excel – FBC

    Nov 29, 2016 · IS 13979 (1994): Method of calculation of efficiency of packaged packaged steam boilers [MED 1: Boilers and Pressure While calculating the efficiency by direct or indirect method it is necessary to clearly understand that the Boiler Excess Air Tune-up.xls Nov 15, 2011 6, Basic Data about your Boiler, Steam System . losses were included in the Get Price

  • Boiler Efficiency Improvement & Heat Loss Explained in

    In real practice, two techniques are usually used to find out boiler performance, namely direct method and indirect method of efficiency calculation. Direct efficiency This is also recognized as the input-output method because it requires only the valuable output like steam and the heat input for estimating the boiler efficiency.Get Price

  • What are Boilers and Their Types? - Engineering Choice

    Heat-loss method (indirect method) Input-output method (or, direct method) The direct method of boiler efficiency test is more usable or more common. Boiler efficiency = power out / power in = Q × (Hg − Hf) / (q × GCV) × . were. Q, rate of steam flow in kg/h; Hg, enthalpy of saturated steam in kcal/kg; Hf, enthalpy of feed water in Get Price

  • Direct Method and Indirect Method Testing of Efficiency in

    1. ENERGY PERFORMANCE ASSESSMENT OF BOILERSGet Price

  • How to Check Gas Consumption of the Boiler

    Mar 24, 2020 · Let's talk about the direct and indirect efficiencies of a boiler in detail. Direct Efficiency. It is a quick method for boiler efficiency calculation. The percentage of total heat output vs heat input is calculated to establish boiler performance. Direct Boiler Efficiency = Heat output / Heat Input X 100 Or Direct Boiler Efficiency = Q X (h2 Get Price

  • Mash Tun heating methods on a Direct Fire system

    Apr 06, 2018 · In an ideal world, we would go with a steam boiler, and have all vessels steam-jacketed, except for the Lauter Tun. However, this being the real world with crazy boiler regulations and hidden costs, we are seriously considering a direct fire system instead. This is fine for the HLT and BKW, but what we're struggling with most is the MT.Get Price

  • Forbes Marshall | SteamPedia | Indirect boiler efficiency

    Indirect Efficiency Calculation & BS845. The method most standards (including IS8753, BS845 etc.) follow is the indirect efficiency calculation method. In this method, each loss is individually calculated, and the sum of these losses is then subtracted from 100 to give efficiency %. So, % Efficiency = 100 - (sum of all losses)Get Price

  • Direct Method and Indirect Method for Boiler Efficiency

    Direct Method and Indirect Method for Boiler Efficiency Calculation-ZBG Get Price

  • (PDF) A CASE STUDY FOR CALCULATION OF BOILER EFFICIENCY …

    There are two methods to determine boiler efficiency: direct method and indirect method. In this study, the efficiency of a fluidized bed boiler having a steam production capacity of 462000 kg/h Get Price

  • Direct and Indirect efficiency in boilers - energypurse.com

    Aug 30, 2016 · Thermal efficiency % of (heat) energy input that is effectively useful in the generated steam BOILER EFFICE CALCULATION 1)DIRECT METHOD: 2) INDIRECT METHOD: The energy gain of the the efficiency is the working fluid (water and steam) different between losses is compared with the energy and energy input 25 content of the boiler fuel. Direct Method. …Get Price

  • boiler direct and indirect steam methods

    Direct Method and Indirect Method for Boiler … Liming · Thermal efficiency % of (heat) energy input that is effectively useful in the generated steam BOILER EFFICE CALCULATION 1)DIRECT METHOD: 2) INDIRECT METHOD: The energy gain of the the efficiency is the working fluid (water and steam) different between losses is compared with theGet Price

  • comparison of direct and indirect efficiency of boiler

    Direct vs. indirect heating technology - SolexGet Price

  • Water Level Controls and Devices - National Board of

    A level indicator, whether it be a gage glass, indirect sensing method, or independent remote, is used on a steam boiler to provide a water level reading. A gage glass is the most common form of level indicator found on steam boilers.Get Price

  • 1. ENERGY PERFORMANCE ASSESSMENT OF BOILERS

    Indirect Method. Direct method: Direct method is quick method for boiler efficiency calculation, In this method, Percentage of total heat output vs heat input is calculated to establish boiler performance. Boiler Efficiency = Heat output / Heat Input X 100. Or Boiler Efficiency = Q X (h2 – h1) / (q X GCV) X 100 Where Q = Qty of steam generated.Get Price

  • two methods calculate boiler efficiency

    Feb 14, 2022 · Direct Method: The direct method of testing boiler efficiency involves comparing the energy of the fluid (water and steam) with the fuel energy. Indirect Method: The indirect method of testing efficiency determines the difference between the losses and the energy input in the boiler. Direct Method of Testing Boiler EfficiencyGet Price

  • two methods calculate boiler efficiency

    179Boiler Efficiency: Introduction and Methods of CalculationIn actual practice, two methods are commonly used to find out boiler efficiency, namely direct method and indirect method of efficiency calculation.How to calculate boiler efficiency by Direct Method 24 Nov 2016 Quantity of steam generated per hour (Q) in kg/hr. · Quantity of fuel used per hour (q) in kg/hr.Get Price

  • 1. ENERGY PERFORMANCE ASSESSMENT OF BOILERS

    Basically Boiler efficiency can be tested by the following methods: 1) The Direct Method: Where the energy gain of the working fluid (water and steam) is compared with the energy content of the boiler fuel. 2) The Indirect Method: Where the efficiency is the difference between the losses and the energy input. 1.6 The Direct Method TestingGet Price

  • An indirect online method for measuring the boiling rate

    Feb 01, 2020 · In this paper, an indirect online method for measuring the boiling rate of BFG boiler economizer is provided. The boiling rate can be obtained by operating parameters of flue gas side and steam–water side of the economizer, based on heat transfer balance calculation. The measuring results can be used as the basis for the operation adjustment Get Price

  • advantages and disadvantages of indirect method of boiler

    Direct and Indirect efficiency in boilersGet Price

  • Thermal Utility Efficiency - aipnpc.in

    The system consists of a 500 kg/hr LPG fired three pass packaged boiler designed to generate steam at 9 bar. The facility allows for understanding various boiler components and functions. The following experiments can be conducted in this facility: • Determination of boiler efficiency by direct and indirect methodsGet Price

  • TO CALCULATE AND IMPROVEMENT IN THE EFFICIENCY OF …

    Boiler is a steam producing equipment, which produce steam with burning of fuel. Mostly coal is used as fuel in boiler. Efficiency of the boiler should be determined by two method, direct method and indirect method. It required miscellaneous parameters for determining the efficiency.Get Price

  • boiler direct and indirect steam methods - vl-logistik.de

    Boiler - WikipediaA boiler is a closed vessel in which water or other fluid is heated. The fluid does not necessarily boil. (In North America, the term "furnace" is normally used if ProducinGet Price

  • 1. ENERGY PERFORMANCE ASSESSMENT OF BOILERS

    Basically Boiler efficiency can be tested by the following methods: 1) The Direct Method:Where the energy gain of the working fluid (water and steam) is compared with the energy content of the boiler fuel. 2) The Indirect Method:Where the efficiency is the difference between the losses and the energy input. 1.6 The Direct Method Testing 1.6.1 Get Price

Discount
7X24 Online