Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

steam boiler Agent drop header

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :steam boiler Agent drop header
  • Supply Capacity : 10 units/month :steam boiler Agent drop header
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Steam Accumulators - Spirax Sarco

    Figure 3.22.1, shows that in each case the demands are almost instantaneous and the peaks are well above the average load. The result of a sudden demand on boiler plant is a pressure drop in the boiler, because the boiler and its associated combustion equipment are unable to generate steam at the rate at which it is being drawn off.Get Price

  • Steam and Condensate - A basic overview of a steam system

    When steam condenses, its volume is dramatically reduced, which results in a localised reduction in pressure. This pressure drop through the system creates the flow of steam through the pipes. The steam generated in the boiler must be conveyed through the pipework to the point where its heat energy is required.Get Price

  • Condensate Water Treatment to Prevent Steam Boiler Pipes

    By contrast, filming amines are not completely soluble, and therefore, cannot be fed directly into a boiler. In fact, feeding this type of amine into a boiler could cause even worse problems than not treating the condensate at all. In order for a filming amine to work properly, it must be direct injected into the steam header.Get Price

  • Newcomen steam engine : definition of Newcomen steam

    The header tank supplied cold water under pressure via a stand-pipe for condensing the steam in the cylinder with a small branch supplying the cylinder-sealing water; at each top stroke of the piston excess warm sealing water overflowed down two pipes, one to the in-house well and the other to feed the boiler by gravity.Get Price

  • The Interactions Between Steam Piping and Boiler Outlet

    Interactions between steam piping and boiler outlet headers are not always fully considered in the original design or retrofit of these fossil plant components. This is surprising since they form an inte- gral path for steam flow from the boiler to the turbine, and the components are seldom separated or iso- lated by a full anchor on the piping.Get Price

  • sizing boiler headers - Boiler and Pressure Vessel

    Aug 13, 2008 · there are 2 interpretations of "header". For the case of a "header type boiler config", the "header' is the common steam transfer pipe from the multiple boilers to the steam user. In that case, the header size is based on limiting the frictional pressure drop and /or noise, vibration and wet steam erosion/corrosion.Get Price

  • Common Steam Boiler Problems & How to Troubleshoot Repairs

    How to Troubleshoot Steam Boiler Problems. To troubleshoot steam boiler problems, consider the issues and the most common causes behind them. You can save time and money by looking at the composition of the water first and progressing from there during the …Get Price

  • Steam Boilers Tech Check 11 Flashcards by Ashur poulis

    A. by blowing down the low water fuel cutoff or allowing the water level in the boiler to drop B. by using steam from the header to keep the boiler warm C. completely dry D by using antifreeze B. a degreasing agent C, a high pressure water hose D. a steam lanceGet Price

  • Kettle Reboiler - an overview | ScienceDirect Topics

    A kettle reboiler (Figure 10.1) consists of a horizontally mounted TEMA K-shell and a tube bundle comprised of either U-tubes or straight tubes (regular or finned) with a pull-through (type T) floating head.The tube bundle is unbaffled, so support plates are provided for tube support. Liquid is fed by gravity from the column sump and enters at the bottom of the shell through one or …Get Price

  • Steam Header - Boiler Steam Header, Steam Distribution Header

    Boiler Non-Return Valve - Valve engineering - Eng-TipsGet Price

  • Boiler Shutdown, - Banks Engineering

    6. Close all the openings to prevent water, steam or air leakage into the unit. Leave open the code required drain valve between the process steam stop valves to prevent back-leakage of condensate from any downstream header that may be pressurized. 7. Isolate the boiler to prevent moisture from reaching the heating surface. 8.Get Price

  • Drop header on residential steam boilers | Plumbing Zone

    Jun 13, 2011 · They are a very good thing for a steam boiler, especially if the existing supply/feed is close to the recommended height above the water line in the boiler. Your supplies off the top of the boiler can go up much higher to the ceiling and back down to the header which has the equalizer and feed the system off the header. Keeps the steam drier.Get Price

  • Amine High Consumption Reasons at Boilers.

    Nov 09, 2019 · BACKGROUND: As we all know that amine injection is one the chemical injection other than oxygen scavenger, phosphate, polymer & anti-foaming agent for boiler water treatment. The amine injection Get Price

  • How NOT to Design a Steam System - The C&S Companies

    Description. Steam header is the main supporting equipment of the boiler to distribute the steam generated by the boiler operation to various pipelines, it also serves as a reservoir that feeds steam to the individual heating circuits.The boiler steam header must be large enough to virtually eliminate pressure drop between the boiler and the beginning of the circuit.Get Price

  • steamheating - Header piping - Google Search

    I'd like to talk about header piping on steam boilers. In older boilers, the boilers were designed to have a very large open space inside, which allowed the water to boil and bubble, but not "wet" the top of the boiler, inside. This allowed for space inside the boiler for the steam to form and let the water drop back down.Get Price

  • Boiler Steam drum internals and function

    May 30, 2018 · Steam drum internals for typical type of boiler are shown. The internals include separation devices to assist in separating small droplets of boiler water from the steam. Boiler water in the steam will cause scaling of the superheater and steam turbines.Baffles, chevron types separators and demister pads are used to minimize boiler water carryover.Get Price

  • FULL-COLOR TRAINING GUIDE SERIES - PB Heat: Peerless® …

    5. If the boiler is severely oversized, the steam flow in the mains will cause too much pressure drop. The water in the returns will rise and water hammer can occur. E. COUNTERFLOW SYSTEMS 1. Basic system piping and operation a) Condensate must flow against the flow of steam b) The boiler header must enter the top of the main on counterflow Get Price

  • US6718915B1 - Horizontal spiral tube boiler convection

    US6718915B1 US10/320,342 US32034202A US6718915B1 US 6718915 B1 US6718915 B1 US 6718915B1 US 32034202 A US32034202 A US 32034202A US 6718915 B1 US6718915 B1 US 6718915B1 Authority US United States Prior art keywords boiler convection pass enclosure spiral tube walls Prior art date Kefid Legal status (The legal status is an assumption and is not …Get Price

  • How Humidifiers Work - Armstrong International

    The steam supply itself acts as a cleaning agent to keep system components free of mineral temperature drop Small Small Poor Slow Slow Weekly to monthly Low High Direct Steam Small to very large the boiler. There is no mineral dust deposited, and because there is no liquid moisture present, steam Get Price

  • Sulfites for Oxygen Control - Scranton Associates

    diluted and as alkalinity increases in the boiler. This allows any free erythorbate present to catalyze the sulfite/oxygen reaction and validates it as a safe, non-metallic agent of catalysis. The usual catalyst for sulfite had been cobalt sulfite or cobalt chloride at …Get Price

  • GAS SUPPLY APPLICATION GUIDE - AERCO

    May 15, 2015 · Boiler gas manifold piping should be sized based on the volume requirements and lengths between boilers and the fuel main. Header sizes can be either full size or stepped in size as units are connected. A typical gas piping header diagram for two AERCO AM Series boilers is illustrated in Figure 2. Header should be located above or behind boiler.Get Price

  • Steam Headers and Off Takes | Spirax Sarco

    The main observation is that this design of distribution header does not allow the boilers to share the load equally. The aim should be that the pressure drops between each boiler outlet and the header off-take to the plant should be within 0.1 bar. This will minimise carryover and help to prevent overload and lockout of boilers.Get Price

  • Steam Pressure Reduction: Opportunities and Issues - Energy

    6. If, prior to reducing boiler steam pressure, the boiler is already having carryover issues, these should be addressed before considering reducing the boiler steam pressure. Steam System Losses and Savings Through Pressure Reduction A List of Boiler and Steam System LossesGet Price

  • Repiping A MegaSteam Steam Boiler - Part 2 - Drop …

    The drop header(s) piping is sized to match the two top tappings in the steam chest which lets the boiler make more dry steam at a faster rate through the twin steam chest tappings and also making the boiler more efficient in the process in making dry steam using a common condensate drain from the drop headers back to the boilers water level. The drop headers also allow the …Get Price

  • U.S.C.G. Merchant Marine Exam Third Assistant Engineer

    o (B) back pressure in the steam drum acting on the user tubes o (C) high feedwater pressure • (D) fluid friction in the downcomers, drums, generating tubes, and headers If choice D is selected set score to 1. 3. Proper bracing and support of the boiler safety valve escape piping is …Get Price

  • Discussion Of Oil Fired Steam Boiler Install With Drop Header

    Sep 12, 2021 · Oil Fired Weil Mclain SGO 8 section steam boiler installed with a threaded steel pipe drop header.The equalizer line, Hartford Loop and Hydrolevel VXT-120 auGet Price

  • Boiler Steam Headers | Steam header | Tpp Boilers Pvt. Ltd.

    What is a low loss header? | ViessmannGet Price

  • Water Handbook - Steam Purity | SUEZ

    Steam purity should not be confused with steam quality. Steam quality is a measure of the amount of moisture in the steam. It is expressed as the weight of dry steam in a mixture of steam and water droplets. For example, steam of 99% quality contains 1% liquid water. Carryover is any solid, liquid, or vaporous contaminant that leaves a boiler Get Price

  • Weil McLain Oil Fired Steam Boiler Glass Piping - Needs

    Credit to: https://youtube.com/channel/UCA_ZKNA-k-nA4eH5qNb3jXAFor posting this video on his channel Join this channel to get access to perks:https://.youGet Price

  • Boilers - University of Alabama

    Fire-Tube Boiler (~1800) The fire tube boiler, the oldest design, is made so the products of combustion pass through tubes surrounded by water in a shell. The furnace/flame volume can either be inside or external to the shell that contains the water. The upper steam capacity of fire tube boilers is about 20,000 Ibm/hr, and the peak pressureGet Price

Discount
7X24 Online